MicroWYND Cartridge Filters are special wound filters produced by combining two different materials on a support core located inside thanks to CUNO’s patented special production technology.
  Unlike traditional wound filters, the filter texture is formed by the fiber part that wraps around the support core in the form of a cover and the yarns that are spirally wound around it with a certain tension and tightness. The spiral winding of the yarns is done in a way that creates large diamond shapes; thus, the flow performance and filter service life reach the highest level of qualifications.

 
SCOPE OF APPLICATION

INDUSTRIAL –  Machinery Equipment Oils, Chemicals, Process Water, Pre-RO FOOD & BEVERAGE –  Water and Pre-RO 

 

CHEMICAL  – Water, Solvents, Acids, Chemical products

OTHER  –  Electronics, Electro-Plating applications

 


FEATURES & BENEFITS
  • Fiber Wound Filter Cartridge –  Provides high Filtration efficiency at the specified Filtration degree.
  • Graduated Density Filter Path –  Provides reduced pressure drop and high flow performance, extending filter life and reducing filtration costs.
  • Low Extractable Levels –  Suitable for Water, Electronics and Electroplating.
  • Different Filter Material –  Ensures suitability for process and system.
  • High Dirt Holding Capacity –  Reduces filter change frequency.
  • Wide Range of Connection Options –  Compatible with all filter chambers.
  • Higher Quality and Durable Structure –  The possible risk of fiber escape in standard wound filters is eliminated due to the special structure of Micro WYND.
  • COMPLIES WITH FDA 21CFR .


MICRO WYND II FILTER SPECIFICATIONS
FILTER MATERIAL   
PPP Tip POLYPROPYLENE CLOTH, YARN AND SUPPORT CORE
CCS TipCOTTON CLOTH, YARN AND 304 SS (STAINLESS STEEL) SUPPORT CORE
CCT TipCOTTON CLOTH,YARN AND 316 SS STAINLESS STEEL)SUPPORT CORE
*MicroWYND Filters can be supplied in different material combinations upon request, in certain order quantities.
OPERATION PARAMETERS    
Maximum Operating Temperature    82 °C (PPT TİP)      
120 °C (CCS VE CCT TİP )
Maximum Differential Pressure5 bars @ 20 °C

Recommended Differential Pressure  for Filter Replacement 
2.5 bar @ 30 °C
Filtration Degree 0.5µ, 1µ, 3µ, 5µ, 10µ, 25µ, 50µ, 75µ, 100µ, 350µ 
DIMENSIONS
Outside Diameter2,5 inch
Inner Print1,1 inch
Length97/8, 191/2, 20, 291/4, 30, 39, 40 inch

Distribution channel

Graph 5.  MICRO WYND II – Competitor Filter  Flow Comparison

MICRO WYND II ORDERING GUIDE
Distribution channel